Panasonic A4 Series Power Supply User Manual


 
96
Wiring to the Connector, CN X5
Connecting Example to Host Controller
Matsushita Electric Works, FPG-C32T
2k
2k
5.6k
3k
5.6k
5.6k
220
220
4.7
k
4.7
k
4.7
k
4.7
k
4.7
k
4.7
k
CW
pulse command 
output
CCW 
pulse command 
output
CW 
pulse
command
input
Y0
Y1
X2
COM
+
Y2
COM
X3
X5
X6
PULS1
PULS2
SIGN1
SIGN2
CZ
GND
COM+
CL
SRV-ON
GAIN
A-CLR
CCWL
CWL
S-RDY+
S-RDY–
ALM+
ALM–
COIN+
COIN–
COM–
3
4
5
6
19
13
7
30
29
27
31
9
8
35
34
37
36
39
38
41
CCW 
pulse
command
input
Origin input
Deviation 
counter reset output
Counter clear
input
Servo-ON 
input
Servo-Ready
output
Servo-Alarm
output
Positioning 
complete 
output
Gain 
switching 
input
Alarm clear
input
CW 
over-travel
inhibit input
CCW 
over-travel
inhibit input
PLC
FPG-C32T(FP)
Driver
A4-series
Z-phase 
output
Origin proximity 
sensor
CW limit 
sensor
CCW limit 
sensor
from
PLC I/O 
outpu
t
to
PLC I/O 
input
GND + 24V
DC24V 
Power supply
Origin proximity 
input
CCW limit excess 
input
CW limit excess 
input
represents twisted pair wire.
<Remark>