Panasonic A4 Series Power Supply User Manual


 
252
When in Trouble
What to Check ?
Protective Function (What is Error Code ?)
• Various protective functions are equipped in the driver. When these are triggered, the motor will stall due
to error, according to P.43, "Timing Chart (When error occurs)"of Preparation, and the driver will turn the
Servo-Alarm output (ALM) to off (open).
• Error status ands their measures
During the error status, the error code No. will be displayed on the front panel LED, and you cannot turn
Servo-ON.
• You can clear the error status by turning on the alarm clear input (A-CLR) for 120ms or longer.
• When overload protection is triggered, you can clear it by turning on the alarm clear signal (A-CLR) 10
sec or longer after the error occurs. You can clear the time characteristics by turning off the connection
between L1C and L2C or r and t of the control power supply of the driver.
•You can clear the above error by operating the front panel keys.
(Refer to P.73, "Alarm Clear Mode" of Preparation.)
•You can also clear the above error by operating the "PANATERM
®
".
<Remarks>
• When the protective function with a prefix of "*" in the protective function table is triggered, you cannot
clear with alarm clear input (A-CLR). For resumption, shut off the power to remove the cause of the error
and re-enter the power.
• Following errors will not be stored in the error history.
Control power supply under-voltage protection (Error code No. 11)
Main power supply under-voltage protection (Error code No. 13)
EEPROM parameter error protection (Error code No. 36)
EEPROM check code error protection (Error code No. 37)
Over-travel prohibition input protection (Error code No. 38)
Motor self-recognition error protection (Error code No. 95)
Host
controller
Aren't the parameter 
setups wrong ?
Motor does not run.
Check the cause by referring to P.68, 
“Display of Factor of No Motor Running” of 
Preparation, and then take necessary measure.
Is the wiring to CN X5 correct ?
Or aren't any wires pulled off ?
Is the wiring to CN X6 correct ?
Or aren't any wires pulled off ?
Is the wiring to CN X7 in case 
of full-closed control correct ? 
Or aren't any wires pulled off ?
Isn't error code No. is displayed ?
Ground
Motor
External scale
Machine
Is the connecting portion
disconnected ?
(Broke wire, contact)
Is the wiring correct ? 
Isn't the connector pulled off ? 
Isn't the short wire pulled off ?
Doesn't the power voltage vary ?
Is the power turned on ?
Any loose connection ?
Is abnormal noise generated 
from the motor ?
Isn't the electro-
magnetic brake 
engaged ?
Isn't the connection 
loose ?