Chapter 5 Volume Management
5.2 Functions in the Action Area for Volume
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
137
4 After selecting RAID groups is complete, click the [Start] button.
→ A confirmation screen appears.
5 Click the [OK] button.
→ Migration starts.
6 Click the [Done] button to return to the [Volume] screen.
End of procedure
In the following cases, an error screen appears:
• When the capacity is not specified for "Volume Capacity"
• When "Volume Capacity" does not satisfy the input conditions
• When the "Number of Concatenation RAID Groups" field is left blank, "1" is specified, or a value
that is "65" or more is specified
• When the maximum free space in the selected RAID group is smaller than the volume size that is
to be concatenated
• When an ODX Buffer volume is selected as a migration source volume
To change the concatenation order of the RAID groups, select "Manual" for "Concatenation Order" in
the Volume Information field. Click the [Concatenation Order] link to display the [Setting
Concatenation Order] screen. The concatenation order of the RAID groups can be changed in the
[Setting Concatenation Order] screen.