Fujitsu DX440 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
580
3 Click the [OK] button.
LUN group modification starts.
4 Click the [Done] button to return to the [LUN Group] screen.
End of procedure
An error screen appears in the following conditions:
When the LUN group name, which you entered in the "Name" field, has the same name as an
existing LUN group
When the LUN group name, which you entered in the "Name" field, does not satisfy the input
conditions
When the "Name" field is not input
When the selected volume does not exist
The volume allocation information can be edited while performing the procedure in "9.2.4.1 Add LUN
Group" (page 574).
To add the LUN and the volume allocation, click the [Add] button.
To delete the LUN and the volume allocation information, click the [Delete] button for the
allocation information to be deleted.
To change the LUN and the volume allocation information, delete the allocation information to be
changed. Change the allocation volume, and add it to the LUN group again.
Some LUNs cannot be recognized if one of the following conditions applies to "Host Specific Mode" for
which the host response is allocated to a host group with host affinity settings. When adding LUNs to
a LUN group, check "Host Specific Mode" for the host response.
When "Host Specific Mode" is "Normal (Default)", any LUNs that are added from LUN#256 onward
When "Host Specific Mode" is "AIX Mode" or "NR1000V Mode", any LUNs that are added from
LUN#512 onward
When the "Host Specific Mode" is "HP-UX Mode", any LUNs that are added from LUN#1024 onward