Fujitsu DX440 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
558
Alias Name
Input the Alias Name of the target port.
While the iSCSI name is a formal nomenclature that specifies the target iSCSI port, an Alias Name is
used as nickname.
An Alias Name that is the same as another port cannot be specified.
The following input condition applies:
- Up to 31 alphanumeric characters
General Settings
VLAN ID
Select whether to "Enable" or "Disable" the VLAN ID for the target port.
When "Enable" is selected, specify the VLAN ID between 0 and 4095.
Reset Scope
Specify the reset scope of the target port.
Reset scope is the range where the command reset from the server is performed, when the target
port is connected to multiple servers.
- I_T_L (I: Initiator, T: Target, L: LUN)
Reset (cancel) the command request from the server that sent the command reset request.
- T_L (T: Target, L: LUN)
Reset (cancels) the command request from all of the servers that are connected to the port.
Release Reservation if Chip is Reset
Select whether to "Enable" or "Disable" the function to release the reserved status of the volume
when the target port (chip) is reset.
CmdSN Count
Change the number of commands that can be accepted from the host to the target port at the same
time. It is not necessary to change the default setting (Unlimited) for normal use.
- Unlimited
- 180
- 100
- 80
- 40
- 20
MTU
Specify the MTU size of the target port.
"Maximum Transmission Unit (MTU)" is the maximum amount of data that can be transmitted at
the one time over the communication network.
The following input conditions apply:
- When "IP Version" is "IPv4": 576 - 9000 bytes
- When "IP Version" is "IPv6" or "IPv4 / IPv6": 1280 - 9000 bytes
When specifying the VLAN ID, confirm the VLAN setting values of the LAN switch and the VLAN
tagging configuration of the server LAN card.