11.2.9.3 Export/Delete Log
This function exports and saves the ETERNUS DX Disk storage system maintenance information (log) in
accordance with user-specified time settings.
An exported log can be stored on a floppy disk or hard disk, or sent by E-mail.
Also, users can select a log segment size to suit the destination it is to be saved.
• The maintenance information to be exported
Log to be exported includes an "internal log" and "configuration information".
- Internal log
Detected errors, warnings, and traces
- Configuration definition information
Configuration information exported from the ETERNUS DX Disk storage system
The procedure to export log is as follows:
Procedure
1 Click [Export/Delete Log] in [Action].
2 Set the detailed information for exporting a log, and click the [Export] button.
• Specify Time Range
To specify a time range for exporting logs, select "Yes". Select "No" if not specifying. To export logs
from the last 24 hours, select the "Last 24 hours".
• Start Time
When a time range is to be specified, specify the date and time to start exporting logs.
- YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Date (01 - 31), hh: Hour (00
- 23), mm: Minute (00 - 59), ss: Second (00 - 59))
• End Time
When a time range is to be specified, specify the date and time to finish exporting logs.
- YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Date (01 - 31), hh: Hour (00
- 23), mm: Minute (00 - 59), ss: Second (00 - 59))
• Include I/O Module log
When exporting the I/O module logs, select "Yes". When not exporting, select "No".
• Log File Size
Select the log file size (segment size) when saving the exported log from the following.
- Non-segmentation
- 4.27MB
- 1.44MB (Floppy Disk)
- 640KB (E-Mail)
• The internal log and configuration information cannot be exported separately.
• When exporting of the log has been completed, save the log file immediately.
• The various pieces of maintenance information are combined together, compressed, and then
segmented into the user specified segment size before being exported.
Special tools to read these logs are required.