Chapter 9 Connectivity Management
9.1 Connectivity Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
409
Performance information
Login IP Address
IP address that is logged in is displayed.
The performance information is displayed for each specified IP address. Note that the IPv6 address is
displayed as an abbreviation. If there is no IP address, a "-" (hyphen) is displayed.
This item is displayed for the iSCSI host when the host affinity setting is configured, the iSCSI name is
specified, and the IP address is not specified.
- For IPv4 address
xxx.xxx.xxx.xxx
xxx: 0 - 255 for other fields (decimal)
- For IPv6 address
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (hexadecimal, "a" - "f" are lowercase letters)
Refer to "IPv6 Address Notation" (page 378)
for details.
Performance Monitoring
State
The status of performance monitoring for the host is displayed.
- Active
- Stopped
Start Time
Stop / Collect Time
The start time and the end time for performance monitoring are displayed.
The displayed time varies depending on how the performance monitoring is started or ended.
- Before monitoring is started (*1)
"State" for performance monitoring is "Stopped". "-" (hyphens) are displayed for "Start Time" and "Stop
Collect Time".
- Monitoring is started
"State" for performance monitoring is changed from "Stopped" to "Active". The time when performance
monitoring was started is displayed for "Start Time". The time when the performance information is
obtained is displayed for "Stop / Collect Time".
- Monitoring is started while the monitoring session has already been started
"State" for performance monitoring is "Active". The last time when performance monitoring was started
is displayed for "Start Time". The time when the performance information is obtained is displayed for
"Stop / Collect Time".
- Monitoring is stopped
"State" for performance monitoring is changed from "Active" to "Stopped". The last time when perfor-
mance monitoring was started is displayed for "Start Time". The time when performance monitoring is
stopped is displayed for "Stop / Collect Time".
- Monitoring is stopped while the monitoring session has already been stopped
"State" for performance monitoring is "Stopped". The last time when performance monitoring was
started is displayed for "Start Time". The first time when performance monitoring was stopped is
displayed for "Stop / Collect Time".
*1: When performance monitoring is not being performed after the ETERNUS DX Disk storage system is started.
In the following conditions, "-" (hyphens) are displayed for "Start Time" and "Stop / Collect Time".
When no iSCSI host with the host affinity setting is connected
When no IP address for an iSCSI host with the host affinity setting is logged in
When the start time is "0"