Chapter 11 System Management
11.1 System Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
732
• Date
The date and time when the event occurs are displayed.
- YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Day (01 - 31), hh: Hour (00 - 23),
mm: Minute (00 - 59), ss: Second (00 - 59))
• Box ID
The Box ID is displayed.
Box ID is the information to be used for application software to define the remote device. The initial Box ID
is a device ID that is created by combining device information (series name, model, serial number, etc.).
• Cache Mirroring (Current / After Power OFF ON)
The current cache mirroring setting and the cache mirroring setting after rebooting is displayed in "Current
/ After Power OFF ON" format.
- Enable
- Disable
• I/O Offloading (Current / After Power OFF ON)
The current I/O offloading setting and the I/O offloading setting after rebooting is displayed in "Current /
After Power OFF ON" format.
- Enable
- Disable
• Encryption Mode
The encryption mode setting is displayed.
- Fujitsu Original Encryption
- AES
- "-" (hyphen)
• SMI-S (Current / After Power OFF ON)
The current Storage Management Initiative - Specification (SMI-S) setting and the SMI-S setting after
rebooting is displayed in "Current / After Power OFF ON" format.
- Enable
- Disable
• This item is displayed only when all of the following conditions are satisfied:
- When logged in using a user account with the "Storage Management" or the "Maintenance
Operation" policy
- When using the ETERNUS DX80 S2/DX90 S2 or the ETERNUS DX410 S2/DX440 S2
• When different settings are specified for "Current" and "After Power OFF ON", reboot the ETERNUS DX
Disk storage system.
• This item is displayed only for ETERNUS DX8700 S2.
• When different settings are specified for "Current" and "After Power OFF ON", reboot the ETERNUS DX
Disk storage system.