Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
534
Release Reservation if Chip is Reset
Select whether to "Enable" or "Disable" the function to release the reserved status of the volume
when the target port (chip) is reset.
REC Line No.
Select the REC line number of the target port.
The REC line number is used to switch the communication path when a line fails. The REC line
number is used to recognize failed lines. Set different REC line numbers for each physical
communication path. When lines are in normal status, an REC can be performed regardless of the
REC line number (specifying the same REC line numbers is allowed) in the same way as
conventional REC operations. Note that no priority applies to REC line numbers.
REC Transfer Mode
Select which REC transfer mode is enabled or disabled for the target port.
When "Enable" is selected, an REC is performed in the selected transfer mode for the target port.
When "Disable" is selected, an REC is not performed in the selected transfer mode for the target
port.
To set the REC transfer mode for the specific port, enable the appropriate mode. For example,
specify different ports for Consistency and Stack to perform data transfers without any interference.
The current setting is retained even when an REC path is changed. When "Enable" is selected for all
of the REC transfer modes (default setting), a conventional REC is performed.
- Sync (REC in synchronous transfer mode)
- Async Stack (REC in asynchronous stack mode)
- Async Consistency (REC in asynchronous consistency mode)
- Async Through (REC in asynchronous through mode)
This item is displayed only when "Port Mode" is "CA/RA".
When a line fails, the communication path is switched according to the REC line number of the
copy source storage system. For normal operation, set the same REC line number for the copy
source and the copy destination storage systems to recover data.
If the port mode has been changed from "CA/RA" to "CA" or "Initiator", the REC line number
returns to the default setting ("0"). When the port mode has changed from "CA/RA" to "RA", the
current REC line number setting is retained. Refer to "9.2.3.11 Modify Port Mode" (page 571)