Fortinet 548B Switch User Manual


 
- 695 -
Command Buttons
Submit - Applies the new configuration and causes the changes to take effect. These changes will
not be retained across a power cycle unless a save configuration is performed.
11.3.1.3 Configuring DHCP Snooping Interface Configuration Page
Selection Criteria
Slot/Port - Selects the interface for which data is to be displayed or configured.
Configurable Data
Trust State - If it is Enabled DHCP snooping application considers as port trusted. The factory default
is disabled.
Logging Invalid Packets - If it is Enabled DHCP snooping application logs invalid packets on this
interface. The factory default is disabled.
Rate Limit - Specifies rate limit value for DHCP Snooping purpose. If the incoming rate of DHCP
packets exceeds the value of this object for consecutively burst interval seconds, the port will be
shutdown. If this value is None there is no limit. The factory default is 15pps (packets per second).
The range of Rate Limit is (0 to 300).
Burst Interval - This Specifies the burst interval value for rate limiting purpose on this interface. If the
rate limit is None burst interval has no meaning shows it as N/A. The factory default is 1 second. The
range of Burst Interval is (1 to 15).
Command Buttons
Submit - Applies the new configuration and causes the changes to take effect. These changes will
not be retained across a power cycle unless a save configuration is performed.
11.3.1.4 Configuring DHCP Snooping Static Binding Configuration Page