Cabletron Systems 1800 Switch User Manual


 
11-2 SmartSwitch 1800 4.0 User Guide, Rev 01
Configuring BSC Batch Ports
Once the necessary Node (Chapter 4) and protocol (Chapter 5) parameters have been
configured, press
[A]
at the Port Configuration Menu (or
[A], [C], [A]
from the Main
Menu. When prompted, enter a port number (or press
[Enter]
to accept the default of
0
). Valid port numbers depend on the model of SmartSwitch 1800—see port locations
on page 6-1.
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See Table 11-1 on page 11-
3.) The following figure is an example of an existing port.
Figure 11-1 BSC Batch Port Record
[A],[C],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Pressing
[J]
lists more parameters, and pressing
[K]
displays a screen similar to the fol-
lowing. (All BSC Batch parameters are listed in Table 11-1.)
Node Name=n odexyz
BSC Batch Port Parameters (screen 1 of 2)
* Port: 1 Link State: Linkup
*I/O:V.35
Database System Memory
A Port Type BSC Batch BSC Batch
B Physical Port Interface V.35 V.35
C Blocked Port Flag N N
D Line Speed 9600 bps 9600 bps
E Retransmission Period (ms) 2000 2000
F Maximum Retransmissions 5 5
G Maximum Bytes per Frame 4105 4105
H Generate Clock Y Y
I Rcv Clock (TT) from DTE N N
J Batch Parameters - Screen 2
K Sub scriber I nformation - Screen 3
Option: