12-14 SmartSwitch 1800 4.0 User Guide, Rev 01
Disconnect if Clear Sent
determines whether the user will be logged out if he sends a Clear to the network.
Also, if
Disconnect Timer
and
Disconnect Duration
are set to values other than
0
, the
modem signals will be dropped when the user is logged out.
This parameter is automatically disabled on a PVC connection.
Async PAD Type
defines the PAD type for transparent polled/multipoint async operation:
0
= normal (X.3)
1
= HPAD
2
= TPAD
Devices Connected
is the number of devices connected to the async port. This value must be
1
for X.3
PAD and TPAD.
Assemble Full Message
assembles (if
Y
) incoming packets from the remote device (assuming M-bit is set) into
a complete message before forwarding it to the local async device.
This function works only if the M-bit is set in packets from the
remote device.
Data Forwarding Criteria
specifies (as currently implemented) that the async PAD profile parameters will
determine when data is forwarded.
Special Forwarding Char
is not implemented in the current release.
Dynamic Signaling Action
is not implemented in the current release.