Cabletron Systems 1800 Switch User Manual


 
Async Terminal Operations A-5
SmartSwitch 1800 Asynchronous PAD
– is the default welcome message, displayed
when the terminal is switched on and DSR and DCD become active. When the node
boots, the software looks for a file named BANNER.TXT (which does not exist when
the software is sent to the customer). If the file is not present, the default banner is dis-
played. Any text editor can be used to create BANNER.TXT, which can consist of up
to 256 bytes of ASCII and
[Esc]
characters. (The
[Esc]
characters can be used to
activate ANSI screen functions for line drawings, enhanced characters, etc.) Copy the
file to the OMNI4000 directory, then reboot the node, and the new banner will be in
effect.
Error Codes Sent to Async PAD Port
Clearing Causes
OCC
Number Busy
NC
Network Congestion
INV
Invalid Facility
NA
Access Barred
ERR
Local Procedure Error
RPE
Remote Procedure Error
NP
Not Obtainable
DER
Out of Order
PAD
Invitation to Clear
DTE
DTE Originated
Reset Causes
DTE
DTE Originated
DER
Out of Order
RPE
Remote Procedure Error
ERR
Local Procedure Error
NC
Network Congestion
DO
DTE Operational
NO