Cabletron Systems 1800 Switch User Manual


 
13-8 SmartSwitch 1800 4.0 User Guide, Rev 01
Configuring Voice Ports
To configure a Voice port, press
[D]
at the Voice Configuration Menu (or
[A], [C], [D]
from the Main Menu. When prompted for a
Port Number
, enter
4
or
5
.
Figure 13-4 Voice Ports
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See Table 13-4.) The fol-
lowing figure is an example of an existing port.
Figure 13-5 Voice Port Screen 1
[A],[F],[D]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Pressing
[J]
will display a second screen (from which two more screens can be dis-
played). The parameters for all screens are listed in Table 13-4.
Voice 1 (Port 4)
Voice 2 (Port 5)
Node Name=node_xyz
Voice Port Configuration Parameters (screen 1 of 2)
* Port: 4 Link State: Linkup
* I/O: VOICE Database System Memory
* Port Type VOICE
* Physical Port Interface RJ45
A Blocked Port Flag N N
B Rate 8 8
C DTMF Detection 1 1
D Timed E Timer 3 3
E Input Level 0 0
F Output Level -4 -4
G I n Hu nt Group No No
H S LT Time-out 30 30
I Li nk D own Busy Y Y
J Additional Parameters
Option: