Cabletron Systems 1800 Switch User Manual


 
22-8 SmartSwitch 1800 4.0 User Guide, Rev 01
Meaning: The port statistic
Receive Error Ratio
has exceeded the threshold
(
T:“n”
) that was set by the user. (
C:“n”
is the current value.) The
Receive Error Ratio is the ratio of frames rejected per second to
frames accepted per second.
Action: If this happens frequently, check the line for noise, and check for
configuration errors on both the port and the connected device.
318.
Rcv Port Usage exceeded T:“n” C:“n”
Severity: 4
Meaning: The port statistic
% Receive Port Util
(Utilization) has exceeded the
threshold (
T:“n”
) that was set by the user. (
C:“n”
is the current
value.) Percent of Receive Port utilization is the ratio of non-flag
characters to total characters being received by the port.
Action: If this happens frequently, you may need to add ports or reroute
some traffic.
319.
Trn Port Usage exceeded T:“n” C:“n”
Severity: 4
Meaning: The port statistic
% Transmit Port Util
(Utilization) has exceeded the
threshold (
T:“n”
) that was set by the user. (
C:“n”
is the current
value.) Percent of Transmit Port Utilization is the ratio of non-flag
characters to total characters being received by the port.
Action: If this happens frequently, you may need to add ports or reroute
some traffic.
400.
Link Enabled
Severity: 2
Meaning: The port has been enabled from the On-Line Port Operations Menu.
Action: None.
401.
Link Disabled
Severity: 2
Meaning: The port has been disabled from the On-Line Port Operations Menu.
Action: None.
402.
Link Disconnected
Severity: 2
Meaning: For frame relay or X.25, this means that the link is disconnected and
level 2 cannot be established.
For SNA TPAD, this means that an XID command frame has been
issued by the TPAD, but either there has been no response or the
received XID data does not match the XID data configured for the
TPAD subscriber. For SNA HPAD, this means that no XID or
SNRM command frame has been received for any link address con-
figured for the HPAD subscriber.