Cabletron Systems 1800 Switch User Manual


 
System Events 22-23
541.
DLCI “n” Frame Relay Header Invalid
Severity: 3
Meaning: The header contained an invalid DLCI.
Action: Check the configuration record for the port.
542.
DLCI “n” PVC does not exist
Severity: 3
Meaning: Self-explanatory.
Action: Create a PVC record.
543.
DLCI “n” Frame Discarded - CIR
Severity: 3
Meaning: A frame was discarded, probably because the excess burst size (B
E
)
was exceeded.
Action: The frame must be resent.
545.
DLCI “n” frame relay PVC deleted
Severity: 4
Meaning: Self-explanatory.
Action: None.
546.
DLCI “n” frame relay PVC connected
Severity: 4
Meaning: Self-explanatory.
Action: None.
547.
DLCI “n” Data Received on Inactive PVC
Severity: 3
Meaning: One end of the PVC is probably not up.
Action: Check both ends of the PVC.
548.
DLCI “n” No STATUS ENQ Received
Severity: 3
Meaning: No Status Enquiry was received when one was expected.
Action: Check the remote device.
561.
LLC Interface File Upd:LLC2IPAR.DAT
Severity: 4
Meaning: The LLC2 Interface file has been updated.
Action: None.