Cabletron Systems 1800 Switch User Manual


 
System Events 22-21
520.
BSCI:Invalid CRC operations
Severity: 3
Meaning: An invalid operation has occured, and has disabled the port.
Action: Re-enable the port (
[B], [A], [C]
from the Main Menu).
521.
BSCI:Invalid queue operations
Severity: 3
Meaning: An invalid operation has occured, and has disabled the port.
Action: Re-enable the port (
[B], [A], [C]
from the Main Menu).
522.
BSCI:Invalid protocol operations
Severity: 3
Meaning: An invalid operation has occured, and has disabled the port.
Action: Re-enable the port (
[B], [A], [C]
from the Main Menu).
523.
BSCI:Invalid CUA, DUA operations
Severity: 3
Meaning: An invalid operation has occured, and has disabled the port.
Action: Re-enable the port (
[B], [A], [C]
from the Main Menu).
524.
Invalid Line Speed Port “n”
Severity: 3
Meaning: Self-explanatory.
Action: Correct the line speed in the Port record.
530.
I-FRM Blocked-Remote Busy Timeout
Severity: 2
Meaning: An RNR (Receive Not Ready) condition on the port has been
cleared by expiration of the Remote Busy Timer, which caused the
port to be reset.
Action: Check the user device for a problem that caused the RNR.
531.
I-FRM Blocked-No Acks from Remote
Severity: 2
Meaning: The remote user device is not accepting transmission from the local
device, and the local port has been reset.
Action: Check the remote device for a problem.
532.
Enter Service Affecting Condition
Severity: 2