FRM Configuring Frame Relay 7-9
Configuring Frame Relay Ports
Once the necessary Node (Chapter 4) and RLP (Chapter 5) parameters have been con-
figured, press
[A]
at the Port Configuration Menu (or
[A], [C], [A]
from the Main Menu.
When prompted, enter a port number (or press
[Enter]
to accept the default of
0
). Valid
port numbers depend on the model of SmartSwitch 1800—see port locations on
page 6-1.
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See Table 7-3 on page 7-14
and Table 7-4 on page 7-15.) The following figure is an example of an existing port.
Figure 7-3 Frame Relay Port Screen 1
[A],[C],[A]
from Main Menu
If
Physical Port Interface
(item B) is configured as
DSU
, items G and H will
be different.
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Pressing
[O]
will display a screen similar to the following figure.
Node Name=node_xyz
Frame Relay Port Parameters (screen 1 of 2)
* Port: 0 Link State: Linkup
* I/O: UNIVERSAL
Database System Memory
A Port Type Frame Relay Frame Relay
B Physical Port Interface V.35 V.35
C Blocked Port Flag N N
D Line Speed 64K bps 64K bps
E Maximum Bytes per Frame 1600 1600
F Logical DCE N N
G Generate Clock N N
H Rcv Clock (TT) from D TE N N
I Link Management 2 Annex D 2 Annex D
J N1 Polling Count 6 6
K N2 Error Threshold 3 3
L N3 Monitored Events Count 4 4
M T1 Link Integrity Timer 10 10
N T2 Polling Verification Timer 15 15
O Additional Parameters
Option: