System Events 22-11
416.
PAD Autocall Retries Exhausted
Severity: 3
Meaning: The async PAD retry timer has expired without a connection being
established.
Action: None; however, if this occurs with any frequency, you may want to
increase the timer (
Retry Count
) or check the remote async device for
problems.
417.
Frame Relay Link Failed
Severity: 1
Meaning: The physical link is down.
Action: Check the cables for secure connections and proper operation.
426.
PU Status p = "n" stn = 0x"n" status = "n"
Severity: 2
Meaning: The SDLC PU status has changed.
Action: None.
428.
Duplicate of DLCI “n” on Port
Severity: 3
Meaning: Each connection sharing a DLCI must be on a different logical port,
and two records have been configured specifying the same logical
port on one DLCI. (DLCIs are configured in records for logical
ports, IP/LLC2/IPX interfaces over frame relay, Bridge ports, and
frame relay PVCs.) Only one of the duplicate connections will come
up.
Action: Check the database records for the duplicate configuration and
change one (or more) of the records.
429.
File Update: FRDLCI.DAT
Severity: 4
Meaning: The Frame Relay DLCI configuration file has been updated.
Action: None.
430.
Received Port Disable Request
Severity: 1
Meaning: A local or remote operator performed a port disable (
[B], [B], [A]
or
[B], [B], [B]
from the Main Menu).
Action: None; however, all users of the port(s) should be made aware of the
disable.
431.
Received Port Dump Request
Severity: 1