Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
1-170 GR2K-GA-0014
Ver. 07-02
Flow control may be classified into three types by transmission priority:
Condition 1: Precedence not determined by TOS.
Condition 2: TOS is rewritten; converted TOS determines precedence.
Condition 3: Precedence determined by input IP packet TOS.
Condition 4: Determines the EXP and priority level.
Condition 5: Determines the priority level by EXP.
Flow control is further classified using the following three conditions:
Condition 1: No reserve bandwidth management.
Condition 2: Detected flows that violate bandwidth reservation are discarded.
Condition 3: When a detected flow violates bandwidth reservation, its priority
is lowered.
Parameters
Description: This parameter specifies the QoS IP frame condition list
number.
Default: Only in display. The entire QoS IP frame condition list is
displayed.
Range of value:
1-1024
Flow Detection Condition Parameters
Description: This parameter specifies an upper-level protocol.
Table 1-83 Configurable Flow Control Parameters by Flow-control Type
Flow Control Parameter
Condition 1 Condition 2 Condition 3
Condition
4
Condition
5
1-1 1-2 1-3 2-1 2-2 2-3 3-1 3-2 3-3 4-1 5-1
-max_priority_class_X * * *
-priority_class <No.>
-discard_class <No.>
*** * *
-replace_tos <New_Tos Value> †† †† ††
-tos_map †† †† ††
-upc {no | <Bandwidth>} *(1) ††(2) ††(2) *(1) ††(2) ††(2) *(1) ††(2) ††(2)
-upc_penalty drop * * *
-upc_penalty
-modified_priority_class <No.>
-modified_discard_class <No.>
††
-upc_penalty
<Modified_New_Tos Value>
†† ††
-replace_exp <Value> ††
††: required, : configurable, *: configurable; default, blank: not configurable, numeral: numeric setting
1: no (or default value)