Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
1-176 GR2K-GA-0014
Ver. 07-02
Change it with the list to be changed not registered in qos-ip-list-group when
changing this parameter.
The flow control parameter below uses the setting value specified in an important
packet when a normal packet is specified in this parameter.
This parameter is valid only in RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV,
GR2000-1B and GR2000-2B.
Description: This parameter sets the same group number in units of groups
that control a band.
Default: None (A band is not controlled in units of groups.)
Range of value: 1-2000 (decimal)
A list with the same number operates as an identical band control group when the
list in which this parameter is specified is set to qos-ip-list-group.
This parameter conforms to the conditions below when it is used.
Change it with the list to be changed not registered in qos-ip-list-group when
changing this parameter.
The maximum number of lists that can be handled as one group is four.
Set and delete a list to and from qos-ip-list-group continuously for each group
number in the order below.
This parameter is valid only in RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV,
GR2000-1B and GR2000-2B.
Table 1-86 UPC Penalty Operation
Default Operation Change Method
Maximum band limitation
(Important)
Drop Cannot be changed.
Maximum band limitation
(Normal)
Drop Cannot be changed.
Minimum band guarantee
(Important)
-modified_discard_class 1 *1 Specified by -modified_discard_class
<No.>.
Minimum band limitation
(Normal)
-modified_discard_class 1 *1 Specified by -modified_discard_class
<No.>. *2
*1: -modified_priority_class uses the class specified by -priority_class.