Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
5-2 GR2K-GA-0014
Ver. 07-02
5.1 Common
Table 5-1 Configuration Error Messages
Message Contents
Can not execute config command, please try
again.
Communication error occurred between processes.Wait for recovery,
then execute again.
Command incomplete because processing
configuration deletion exceeded time limit.To
complete deletion, please try same command
again.
Because processing deletion of configuration is taking too much
time, command is interrupted.Execute same command again.
For example, if this message is displayed during the deletion of line
information, the IP information and line information may not have
been deleted even if the IP routing protocol has been removed.
Configuration file is closed. Current or spare configuration file closed.After opening current or
spare configuration file, execute configuration command again.
illegal option -- <Option> Illegal option entered. Correct the option.
Interface name not found. Specified interface name not found. Specify a correct interface
name.
Invalid subcommand. Subcommand invalid. Enter a correct subcommand.
<item> is not in range <value1> to <value2>. The value is out of range. Set the in-range value.
<item>Parameter name, <value1> Minimum value,
<value2>Maximum value
Logical inconsistency occurred. An internal program complication has occurred in editing and
processing the configuration defining information. Collect the
following log information and deliver it to the maintenance person.
The maintenance person will send the log information to the assisting
department.
[Procedure to collect log information]
1. Set the terminal so that the screen logs can be collected.
2. Execute the following commands.
(1) cat/var/tmp/gen/genTrace_config
(2) cat/var/tmp/gen/genTrace_configManager
(3) /usr/local/diag/configShowBinary
3. Finish collecting the screen logs.
Maximum number of entries are already
defined.
Attempt made to add entries exceeding the limit. Delete unnecessary
entries, then add an entry.
No enough parameters. The parameters are insufficient. Specify the necessary parameters.
No such delete index Because the entered value is illegal, configuration information cannot
be deleted. Enter a correct value.
No such insert index Because the entered value is illegal, configuration information cannot
be inserted. Enter a correct value.
No such <object> The configuration defining information for the name designated in the
<object> is not available. Designate the name of the defining
information being set.
Now another user configured, please try
again.
Another user is currently changing the configuration. Wait for access,
then execute again.
Now configuration data is changing, please try
again.
Configuration information being changed. Wait for the change, then
execute again.
Now configuration file is locked, please try
again.
The operating configuration defining information cannot be edited
because another user is referencing it using the command.
If "more" is displayed in the operation command that indicates the
interface name, finish the "more" display, and execute the command
again. If moreis not displayed, execute it again after a while.
Operation not permitted Because operation configuration information written in memory is
being edited, operation is not permitted.
option requires an argument -- <Option> Option entry insufficient. Correct the option.