Hitachi GR2000 Series Network Router User Manual


 
Configuration Error Messages
GR2K-GA-0014 5-91
Ver. 07-02
5.12 Bridge Information
Table 5-12 Bridge Information Error Messages
Message Contents
Action (drop , forward) not specified. Action (drop, forward) not specified. Set drop or forward.
Duplicate extended filtering. Duplicate extended filtering is set. Set the contents for all of the
extended filtering information to unique.
Duplicate filtering database. Duplicate filtering database is set. Set the contents for all of the
filtering database information to unique.
Interface name not specified. Specified interface name not found. Enter a correct interface name.
Invalid port mode. Port mode is abnormal. Set to no for frame relay interface and DLCI
group interface.
IP interface is not defined. You are about to set the bridge interface for an interface without IP
routing. Before setting the bridge interface, make settings for IP
routing.
Length not specified. Data length is not set. Specify the data length.
MAC address not specified. MAC address is not set. Specify the MAC address.
Maximum number of bridge interfaces are
already defined on the RP.
Maximum number of bridge interfaces are already defined on the RP.
Set 32 or less interfaces per RP.
Maximum number of bridge interfaces are
already defined.
Maximum number of bridge interfaces are already defined on the RP.
Set 160 or less interfaces per router.
No such insert index. An entry cannot be inserted on specified entry number. Use entry
number not exceeding the number of set entries.
No such set index. An entry cannot be set on specified entry number. Use entry number
not exceeding the set number of entries. To add entries, use the
number of set entries +1 for entry value.
Relations between forward delay time and
max age time are inconsistent.
Relations between forward delay time and max age time are
inconsistent. Set to meet 2 x (forward delay time -1) >= max age
time.
Relations between max age time and hello
time are inconsistent.
Relations between max age time and hello time are inconsistent. Set
to meet max age time >= 2 x (hello time +1).