Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
1-44 GR2K-GA-0014
Ver. 07-02
Indication of top blank list number in the specified range
Parameters
Parameters that can be set for each RP type have been determined. The list of
parameters that can be set for each RP type using IPv6 filter flow information is
showninTable1-29ListofParametersthatCanBeSetforEachRPTypeUsingIPv6
Filter Flow Information.
Table 1-29 List of Parameters that Can Be Set for Each RP Type Using IPv6 Filter Flow
Information
Item
Parameter
RP-A1
RP-C, RP-D
RP-C6, RP-D6
GR2000-1B,
GR2000-2B
Main Item Sub-Item
Input
Side
Output
Side
Input
Side
Output
Side
Flow detection
conditions
AllprotocolIPs ip x x √√
Protocol number <protocol No.> x x √√
Protocol TCP tcp x x √√
Protocol UDP udp x x √√
Protocol ICMP icmp6 x x √√
Source IP address <IP_Source> x x √√
Destination IP address <IP_Destination> x x √√
DSCP dscp <DSCP_Value> x x √√
precedence precedence
<precedence_Value>
-- -- √√
IP user data length {upper | lower} <Length> x x √√
Source port number <Port_Source> x x √√
Destination port number <Port_Destination> x x √√
ack flag ack x x √√
syn flag syn x x √√
ICMP6 type <ICMPv6_Type> x x √√
ICMP6 code <ICMPv6_Code> x x √√
Designation of
operation
Relay forward x x √√
Discard drop x x √√
Policy routing policy <Interface Name>
<IP Address>
−−√−
DSCP replace_DSCP
<DSCP_Value>
−−√√(∗1)
Connection branch index <No.> −−−√
Extended header
additional function
scan_extension −−√√
√
: Canbeset.
-: Cannot be set.
x: Can be set when RP-C6, RP-D6, RP-CV, and RP-DV are not installed in this router.