Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
3-12 GR2K-GA-0014
Ver. 07-02
3.1.3 alarm
Function
Object for creation, modification, deletion, and display of RMON (RFC1757) Ethernet
alarm-group information. A maximum of 128 alarm-group entries can be registered
per router. The RMON Ethernet alarm-group MIB contents can be referenced by the
device management command snmp.Forthissnmp command, see the GR2000
Operations Guide.
Input Format
To create an RMON Ethernet alarm-group entry:
To modify an RMON Ethernet alarm-group entry:
To delete registered RMON Ethernet alarm-group entries:
To show registered RMON Ethernet alarm-group entries:
Parameters
Description: Specifies the RMON Ethernet alarm-group index number. This
parameter corresponds to alarmIndex of RFC1757.
Default: Undefined (but cannot be omitted)
Range of value: 1-65535
Description: Sets the object ID of the MIB that checks out the alarm
threshold. This parameter corresponds to alarmVariable of
RFC1757.
Default: Undefined (but cannot be omitted for the first time)
Range of value: Object ID of counter or gauge type in up to 63 alphanumeric
and special characters in dot format enclosed by double
quotation marks. When the string contains only alphanumeric
characters and no special characters except period, you can
omit double quotation marks.