Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
4-34 GR2K-GA-0014
Ver. 07-02
4.7.2 SNMP Information
Input Format
Parameters
The initial value items that can be set using SNMP information and the initial values
during initial installation are shown in Table 4-2. For details of each parameter, refer
to the configuration definition information in "Section 3.1, “SNMP Objects".
Table 4-2 List of Initial Value Items that Can Be Set Using SNMP Information and Initial
Values during Initial Installation
Information
Group Name
Information Name Initial Value
SNMP
information
Reference mode of MIB information Only the reference of MIB information is enabled.
(Read)
Trap transmission mode Not transmitted. (None)
Transmission level of system message
Trap
System message Trap for a fatal failure is transmitted.
(Level 9)
Selection of Trap version Version 1
Transmission level of system message
Trap during trap selection
System message Trap for fatal failure (Level 9)
Limited moment of coldStart trap issuing The moment at which coldStart trap is issued is not
limited. (limited_coldstart_trap)
Number of log entries in which RMON
static information is stored
50 entries
Time interval at which RMON static
information is collected
Static information is collected at intervals of 30 minutes.
Timing in which RMON threshold check
starts
An alarm is generated when the upward or downward
threshold value is exceeded during first sampling.
(rising&falling)
Limited moment of link trap issuing The moment at which link trap is issued is not limited.
(protocol)
Selection of link trap appended
information
When link traps are issued, it is information that
appends MIBS that comply with RFC (standard)