Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
1-42 GR2K-GA-0014
Ver. 07-02
Display of blank list number in the specified range:
Display all blank list numbers in the range in which the list number is 1 to
100 on the Inbound (input) side of interface Tokyo.
Display of top blank list number in all list numbers:
Display the top blank list number in the list numbers on the Inbound (input)
side of interface Tokyo.
Display of top blank list number in the specified range:
Display the top blank list number in the range in which the list number is 51
to 100 on the Inbound (input) side of interface Tokyo.
Related Commands
flow, flow qos, filter, filter-list, qos, qos-ip-list, qos-tos-map, nat, nat inside interface, nat
outside interface
Related Information
None
Precautions
1. The filter flow is determined in the order of the list number designated in the
input/output interface of the filter IP flow information (the indication order when
show flow filter is executed).
2. This command cannot be set when setting the filter-list (filter list information) or
qos-ip-list (QoS IP frame condition information). Delete all of the filter-list and
qos-ip-list before setting this command.
3. The input form for the filter flow information includes two forms: the flow filter
constituting definition information and the filter-list, filter-group and
filter-interface constituting definition information. Features by each input form
are shown in Table 1-9.
4. Flow information consumes 101 entries in each RP when address conversion
(nat) is set. Therefore, when address conversion (nat) is set, the maximum entry
count is decreased by 101 per RP capable of flow information definition.