Hitachi GR2000 Series Network Router User Manual


 
Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
5-70 GR2K-GA-0014
Ver. 07-02
Can not set upc because max_rate or
min_rate is already defined.
The band setting cannot be set because the maximum band
restriction or the minimum band assurance has been defined. To set
the band setting, delete the maximum band restriction or the
minimum band assurance.
Can not set upc because
replace_user_priority is already defined.
It is not possible to set the bandwidth setting because the VLAN
priority rewrite value is defined. Delete the VLAN priority rewrite
value in order to set the bandwidth setting.
Can not set upc_burst because upc not
specified.
The burst size cannot be set because the band setting has not been
defined. To set Upc_burst, set the band setting.
Can not set user_priority. It is not possible to specify "replace_user_priority" except in
interfaces set by OutBound or VLAN.
class out of range The input value is outside the specified range. Set the traffic class in
the range of 0 to 255.
discard out of range The input value is outside the specified range. Set the queuing
priority in the range of 1 to 4.
Duplicate flow interface configuration. Interface names are duplicated. Specify an interface using
"<Interface_Name> + in" as one, and interfaces duplicated either in
Filter or Qos cannot be specified.
Duplicate flow list No configuration. List numbers are duplicated in the interface. Specify for the list
number the numbers not having been set.
entry_no in not in range of 1 to 20000. The input value is outside the specified range. Set the list number in
the range of 1 to 20000.
exp out of range The input value is outside the specified range. Set the exp field value
in the range of 0 to 7.
Filter configuration is already defined. The flow filter cannot be set because filter has already been set.
To set the flow filter, it is necessary to delete the setting of filter_in.
Flow list IP_Address high is less then list
IP_Address.
The IP address (high) is smaller in value than the IP address (low).
Perform the setting so that the IP address (high) is greater in value
than the IP address (low).
FlowlistPort_NohighislessthenlistPort_No
low.
The port number (high) is smaller in value than the port number
(low). Perform the setting so that the port number (high) is greater in
value than the port number (low).
icmp_code out of range The input value is outside the specified range. Set the ICMP code in
the range of 0 to 255.
icmp_type out of range The input value is outside the specified range. Set the ICMP type in
the range of 0 to 255.
icmp6_code out of range The input value is outside the specified range. Set the ICMP6 code in
the range of 0 to 255.
icmp6_type out of range The input value is outside the specified range. Set the ICMP6 code in
the range of 0 to 255.
In case of inbound can not set
replace_user_priority.
It is not possible to specify "replace_user_priority" in InBound of flow
qos. Specify "replace_user_priority" in OutBound.
In case of inbound can not set vlan at VLAN
interface.
It is not possible to specify "vlan" in InBound of flow filter. Specify
"vlan" in OutBound.
In case of outbound can not set policy routing. Policy, Policy_Group, and Policy_MPLS cannot be specified in
OutBound of the flow filter. Specify the Policy, Policy_Group, and
Policy_MPLS in the InBound
In case of outbound can not set user_priority. It is not possible to specify "user_priority" in OutBound of flow qos.
Specify "user_priority" in InBound.
index out of range The input value is outside the specified range. Set the connection
branching index number in the range of 0 to 7.
invalid IP_Address The ip address value is invalid.
invalid IPv6_Address The IPv6 address value is invalid.
list no. in not in range of 1 to 20000, 40001 to
60000.
The input value is outside the specified range. Set the list number in
the range of 1 to 20000 or 40001 to 60000.
Table 5-8 Flow Information Error Messages (continued)