117
CHAPTER 5 TIME-BASE TIMER
Note:
Because oscillation cycles vary immediately after oscillation starts, the oscillation stabilization wait
time is listed for reference.
Watchdog timer
2
22
/F
CH
(Approximately 335.5 ms)
Watchdog timer count up clock
A/D converter
2
8
/F
CH
(Approximately 20.5 µs)
Continuous activation clock
F
CH
: Oscillation frequency
The values enclosed in parentheses are time intervals when the oscillation frequency is 12.5 MHz.
Table 5.1-2 Clock Cycles Supplied by Time-base Timer (2/2)
Clock supplied to Clock cycle Remarks