CHAPTER 9 12-BIT PPG TIMER
Figure 9.6-1 Setting Change during 12-bit PPG Timer Operation
Error
Because the counter start by program is asynchronous with the count-up start by the selected count clock,
an error (a time difference) may occur until detection of synchronization of compare values for the "H"
width and for the cycle period with a count by the counter. A major error may shorten the time before the
above synchronization to one count clock cycle.
Figure 9.6-2 illustrates an error (a time difference) before the count operation start.
Figure 9.6-2 Error before Count Operation Start
(RCR23,24:SCL0 to SCL11)
(RCR21,22:HSC0 to HSC11)
"FFF"
H
* 3
*2
*1
*1
"00"
H
Overflow
Cycle period setting
"H" width setting
Count by counter
Extend by overflow
1 period
PPG output pulse waveform
Because the count interval of the operating counter is less than the changed setting, the setting is
effective only within the cycle.
*1:
*2:
Because a cycle period less than the count interval of the operating counter is set, synchronization
is not detected and the counter overflows.
*3:
Because an "H" width less the count interval of the operating counter is set, synchronization is not
detected until the next cycle.
0 1234
Count by counter
Count clock
1 cycle
Count 0
period
Counter start
Error
(time