6. System Setup
ID Setup and Remote Enable
fa=pÉíìé=~åÇ=oÉãçíÉ=bå~ÄäÉ=
Encore system setup: Step 1.
In this procedure, you will set up individual Encore Video Processor IDs. If ScreenPRO-II,
PresentationPRO-II and/or ImagePRO units are used as destinations, you will also set their
IDs and enable remote control. Each unit in your system must have a unique ID.
Use the following steps to set up IDs and remote control:
1. Power up your Encore Controller, and allow it to fully boot up. This is the system’s
DHCP server.
2. To set Encore Video Processor IDs:
a. Using the Unit ID Selector on the rear of each Processor, set the
desired
ID. Logical IDs 1 - 16 are available.
b. If you elect to use “extended” IDs 17 - 32, use the Video Processors ID
Definition Menu
to redefine the IDs. In Chapter 5, refer to the “Video
Processors ID Definition Menu” section on page 202 for details.
c. Repeat step 3 for all other Video Processors in your system.
3. Power up all Encore Video Processors, ScreenPRO-II units, PresentationPRO-II
units and ImagePRO units in your system. This sequence enables the Encore
Controller to “serve” IP addresses to the Processors and other peripherals.
4. To set ScreenPRO-II and PresentationPRO-II IDs and enable remote control:
a. Ensure that the ScreenPRO-II and PresentationPRO-II units are
connected to the same Ethernet Switch as the Video Processor(s).
b. Press {REMOTE CONTROL} on the Home Menu to access the Remote
Control Menu
.
c. Scroll to the Unit ID line, and select a unique ID. The ID range is 1 to 32.
d. Scroll to the Remote Control/DHCP line, and enable remote control.
e. Press {SAVE} to save the system state in non-volatile memory — so that
it will return to it should power need to be cycled.
f. Repeat step 4 for all other ScreenPRO-II and PresentationPRO-II units in
your system.
5. To set ImagePRO IDs and enable remote control:
a. Ensure that the ImagePRO units are connected to the same Ethernet
Switch as the Video Processor(s).
1
Important
If you are setting up a “stack” configuration, the ID of the
bottom stack Video Processor must always be lower than the
ID of the top stack Processor.
Note
When remote control is on, the {HOME} buttons disappears,
the ScreenPRO-II (or PresentationPRO-II) front panel is
disabled, and the unit’s IP address is dynamically assigned.
All control now originates from Encore’s console.