Tektronix cts710 Surge Protector User Manual


 
Setting SDHSONET Transmit Parameters
3–86
CTS 710 SONET Test Set User Manual
Figure 3–31: Adding Data into the DCC
To add external data into the User Channel:
1. Connect an external protocol analyzer to the CTS 710 using the
Overhead Add/Drop Port on the rear panel of the CTS 710.
2. To configure the CTS 710 to add the external data byte:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TRANSMIT PATH
OVERHEAD
External Add None
F2
H Select None if you do not want to add external data.
H Select F2 to add data, generated by an external protocol
analyzer, to the User Channel.
As soon as you select F2, the CTS 710 displays the words EXT ADD
as the value for F2 (see Figure 3–32).