D-Link dws-1008 Switch User Manual


 
D-Link DWS-1008 CLI Manual 25
Defaults: None.
Access: Enabled.
Usage: You must set the system county code to a valid value before using any set ap commands
to configure an access point.
Examples: To set the country code to Canada, type the following command:
DWS-1008# set system country code CA
success: change accepted.
See Also:
• show config
set system idle-timeout
Specifies the maximum number of seconds a CLI management session with the switch can
remain idle before MSS terminates the session.
Syntax: set system idle-timeout seconds
seconds
Defaults: 3600 seconds (one hour).
Number of seconds a CLI management session can remain idle before MSS
terminates the session. You can specify from 0 to 86400 seconds (one day).
If you specify 0, the idle timeout is disabled.
The timeout interval is in 30-second increments. For example, the interval can
be 0, or 30 seconds, or 60 seconds, or 90 seconds, and so on. If you enter an
interval that is not divisible by 30, the CLI rounds up to the next 30-second
increment. For example, if you enter 31, the CLI rounds up to 60.