FR81 Family
242 FUJITSU MICROELECTRONICS LIMITED CM71-00105-1E
CHAPTER 7 DETAILED EXECUTION INSTRUCTIONS
7.70
7.70 FLD (Single Precision Floating Point Data Load)
Loads the value at memory address Rj to FRi.
● Assembler Format
FLD @Rj, FRi
● Operation
(Rj) → FRi
● Classification
Single-precision floating point instruction, FR81 family
● Execution Cycles
a cycle
● Instruction Format
● EIT Occurrence and Detection
A data access protection violation exception, an invalid instruction exception (a data access error or FPU
absence error), or an interrupt is detected.
MSB LSB
(n+0)000001111100 Rj
(n+2)---FRi