6-6 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB60019−01
Command Basic Definition
TEL4x
TEST LINE 4
Tests to see whether loop current is present on a specific port, where x is the
port number. The port number must be entered in decimals.
. This command is not used for DPNSS integration.
TEL5x TEST LINE 5
Tests tone reflection on one port, where x is the port number.
TE NET x y
TEST NETWORK
Tests network routes to a network location, where x is the network location code
(optional), and y is the non-zero show digits entered. Tests all locations if no
network location is specified.
TE S
TEST STATUS
Tests the temperatures and voltages for the Octel 200/300.
TE INT x y
TEST INTEGRATION
Tells the integration card to run a link self-test, where x is the slot number, and
y is the unit number. Used only for message servers with integration cards.
. This command is not used for DPNSS integration.
T DNET
TEST DNET
Use this command for Digital Networking to get a quick indication of the
general “health” of the configuration and hardware at the local and remote
cabinets.
TEXxyz
TEST FAX
Perform a loopback test on the specified fax channels to verify that the fax
modems can send and receive fax data and to test the TDM bus connection.
Fax-modem data is sent across the Octel 200/300’s TDM bus, using one of the
fax channels as a sender and the other as a receiver. When this transaction is
completed, the fax application processor reverses the direction of the data flow
and repeats the transaction. In this command, x is the slot number, y is the fax
channel, and z is the fax channel. Refer to the Feature Description volume, Fax
Mail Plus chapter.
T SNMP
TEST SNMP
An Octel 200/300 can inform an SNMP manager system when a qualified
hardware error is logged. This command tests the mechanism for an
Octel 200/300 to communicate to an SNMP manager system.
DEX x y Disk EXerciser
Tests all hard disk sectors for read errors, where x is the disk number, and y is
the region number.