Avaya Octel 200 Server User Manual


 
System Errors and Traffic Pegs 8-17
Octel 200/300 S.4.1PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
DATA-2 = REPORTED STATUS
00 = LSP SUCCESSFULLY STARTED
01 = SCSI ERROR WHILE LOADING LSP
DATA-4 = ERROR CODE
02 = CARD TYPE IN SLOT DOES NOT MATCH
CONFIGURED TYPE
DATA-4 = CARD TYPE ACTUALLY INSTALLED
IN SLOT
03 = CONTROL BUS ERROR SLOT EMPTY OR
CARD NON-RESPONSIVE
04 = FILE SYSTEM READ ERROR ACCESSING LSP
IMAGE
05 = CARD IN SLOT REPORTS FATAL DIAGNOSTIC
ERROR
DATA-3 = SUPPLEMENTAL CARD STATUS
06 = BAD START LSP REQUEST
89 = LIC REPORTED LIC IMAGE CHECKSUM
ERROR
DATA-3 = CURRENT SLOT STATE
00 = EMPTY (UNCONFIGURED)
01 = WAITING FOR INITIAL START LSP REPLY
02 = RUNNING
03 = ERROR
01 = NO PORTS CONFIGURED FOR LINE CARD
02 = LINE CARD DISALLOWED BY OCC
03 = TOTAL PORTS > ALLOWED BY OCC
04 = ERROR WRITING START LSP REQUEST
05 = DISK ERROR WHEN SEARCHING FOR LSP CODES
34. Power-ON
Diagnostic Error
Selftest for line cards. Replace LIC as indicated by slot number. 2
For LIC4 For LIC 8, TLC 8
DATA-1 = PORT 1 DATA-1 = PORT 1, PORT 2
DATA-2 = PORT 2 DATA-2 = PORT 3, PORT 4
DATA-3 = PORT 3 DATA-3 = PORT 5, PORT 6
DATA-4 = PORT 4 DATA-4 = PORT 7, PORT 8