Avaya Octel 200 Server User Manual


 
Maintenance Commands 6-57
Octel 200/300 S.4.1PB6001901
Using UPDATE to Modify Application Delays
You can use UPDATE to modify specific application delays. When you modify an application-delay
index, enter the new value in milliseconds, rounded to the nearest 20 ms.
Use the UPDATE program as follows:
- List the current values in the Application Delay Table
- Modify the values
List Command
Use the LIST command to list the current values in the Application Delay Table. The message server
prompts for an individual delay. Enter the application-delay index to be listed.
To list all application delay indexes, press
Enter
. The following is an example of the Application Delay
Table.
.L APP
LST:
APPLICATION DELAY TABLE
INDEX DELAY (msec.)
00
1 7000
2 5000
3 500
4 3000
5 1200
6 1000
7 30000
8 1600
.
.
.
.
251 0
252 0
253 0
254 0
255 0
Modify Command
Use the MODIFY command to change application delays. The message server prompts for the
application-delay index to be modified. Refer to the Modifiable ApplicationDelay Indexes section in
this chapter; only the delays that are listed can be modified at the Maintenance level. Enter the
application-delay index number. Enter the new value, and press
Enter
. The message server displays the
new value.
The delay values are entered in milliseconds and rounded to the nearest 20 ms value.
The following is an example of Application Delay Index 8 being modified to 1000 ms (1 second).
.L APP
.M APP