Avaya Octel 200 Server User Manual


 
6-56 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
FAST BUSY MAXIMUM TONE ON PERIOD
The longest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is longer than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MINIMUM TONE ON PERIOD
The shortest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is shorter than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MAXIMUM TONE OFF PERIOD
The longest delay that a TONE OFF can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE OFF is longer than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MINIMUM TONE OFF PERIOD
The shortest delay that a TONE OFF can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE OFF is shorter than this delay, the message server
assumes that it is not a fast-busy tone.
Coordinate the following application-delay indexes for cadence recognition. Refer to Table 6-3.
- Set index 49 to a value equal to the largest value for any of the following delay indexes: 53, 61, 63,
69, or 71.
- Set index 50 to a value less than the value for any of the following delay indexes: 54, 62, 64, 70, or 74.
- Set index 51 to a value equal to the largest value for any of the following delay indexes: 55, 65, 67,
71, or 75.
- Set index 52 to a value less than the value for any of the following delay indexes: 56, 66, 68, 72, or 76.
Table 6-3 Application Delays for Cadence Recognition, for Determining Tone On/Tone Off
TONE EVENT
Maximum
Tone On
Minimum
Tone On
Maximum
Tone Off
Minimum
Tone Off
Single Interrupt Ringback Index 53 Index 54 Index 55 Index 56
Max/Min Acceptable Tone Ranges Index 49 Index 50 Index 51 Index 52
Double Interrupt Ringback, long periods Index 61 Index 62 Index 65 Index 66
Double Interrupt Ringback, short periods Index 63 Index 64 Index 67 Index 68
Slow Busy Index 69 Index 70 Index 71 Index 72
Fast Busy Index 73 Index 74 Index 75 Index 76
73
74
75
76