8-8 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB60019−01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
5: Ring Through TEST LINE 2
PORT
Verify that extension numbers in the table
are correct. Could be a problem in PBX
extensions or LIC.
2
6: Floppy Disk
Controller
During read or write
to floppy
Clear Hardware Error Table, run TEST
FLOP 1. Check cables. If errors repeat,
replace CPU.
1
8: VCU Online Online diagnostic tests Replace VCU. Reboot message server. If
error repeats, replace CPU. If problem
continues contact technical support center.
3
10:Disk getting full Disk message capacity
is all used up or
getting there.
For DATA-1=03 and DATA-2=00−06, and
11 errors, erase messages or increase hard
disk capacity. For DATA-2=10 errors, call
your technical support center.
3
DATA-1 = 01 = ALARM THRESHOLD CONFIGURED IN SYSTEM
PARAMETER 108 REACHED
03 = DISK FULL OR CANNOT MAKE MESSAGE REDUNDANT
DATA-2 = 00 = NO VOICE FILE SLOTS LEFT
01−06 = LOGICAL DRIVE ID THAT IS FULL
0a = PROMPT AREA FULL
0b = NO DISK WITH SUFFICIENT SPACE AVAILABLE
0c = SYSTEM RECORDING LIMIT EXCEEDED (ZERO HOUR DRIVES)
DATA-3 = NOT USED
DATA-4 = NOT USED
11: Disk Initialization
Failure
VCU could not
successfully initialize
the disk(s). Either no
valid system disk is
present in the system,
or no valid file system
exists on the system
disk.
Contact your technical support center. 3
DATA-1 = REASON:
01 = NO SYSTEM DISK FOUND
02 = NO VALID FILE SYSTEM FOUND
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED