Avaya Octel 200 Server User Manual


 
Hardware 2-11
Octel 200/300 S.4.1PB6001901
Power Supply Unit (PSU)
There are eight different Power Supply Units (PSUs) for the Octel 200/300. The differences between
the PSUs are explained in this section.
. The information in this section applies to all PSUs unless otherwise noted.
Caution!
A PSU with the correct input voltage must be
used.
Do not install or remove the PSU with the
power switch in the ON position.
Earlier Version PSUs Current Version PSUs
Octel 200 90–132 VAC
(110/220 VAC nominal)
Octel 200 100240 VAC
autoranging
Octel 200 180–260 VAC
(220/230 VAC nominal)
Octel 300 90–132 VAC
(220/230 VAC nominal)
Octel 300 100240 VAC
autoranging
Octel 300 180–260 VAC
(220/240 VAC nominal)
Octel 200 48 VDC (unchanged) Octel 200 48 VDC (unchanged)
Octel 300 48 VDC (unchanged) Octel 300 48 VDC (unchanged)
PSU Identification
You can identify which PSU is in your Octel 200/300 by the label as listed below:
Current AC PSU Earlier AC PSU
The front label: 100240 VA C PS U
The bar code label: Part Number*
Octel 200 only:
P.S. Warning/Fuse Label:
Size: 5x20mm
Rating: 6.3 Amp, 250V, Slow Blow
Front Label Octel 200 120VAC: AC PSU
Front Label Octel 300120VACl: AC PSU
Front Label Octel 200 230VAC: 230 VAC PSU
Front Label Octel 300 240VACl: 240 VAC PSU
Octel 200 only:
P.S. Warning/Fuse Label:
(Three check boxes for three possible fuses 10 A,
5A,or15A).
Replacement fuse: 250V, Fast Blow.
*The actual part number is on the back of the PSU. Refer to Table 2-3 for the actual part numbers.