The following System Parameters are particular to the requirements for the UK. The installation engineer
must verify that these parameters have the following assignments:
Number
System Parameter Name Value
68 NET:REMOTE DELIVERY ATTEMPT LIMIT 20
69 NET:REMOTE DELAY BEFORE RETRY (MINUTES) 10
. Delays in dialing strings (D character) between the PABX access code and the rest of the digits
must be between 3.5 and 8 seconds. Set D character timing in System Parameter 28 —
“D”
CHARACTER DELAY TIME
.
INFORMATION Table Indices
The following INFORMATION Table indices are particular to the requirements for the UK. The installation
engineer must verify that these indices have the following assignments:
Number
Information Table Index Name Value
15 OFFSITE SPEAK 4
16
OFFSITE SPEAK DELAY
5
The values for INFORMATION Table Indices 15 and 16 must be set so that the total offhook time is less
than 60 seconds. The above values meet that specification