Call Processing Trace Activities 7A-5
Octel 200/300 S.4.1
PB60019−01
Table 7A-2 EVENT and AUX Activities in Call Process Trace Log (continued)
TYPE
Column
Entry
DESCRIPTION
AUX
Column
Entry
DESCRIPTION
EVENT
Column
Entry
FAX_MSG END_PLAY The playing of the message has ended. The CPT shows result codes for fax transactions in the AUX
column. For fax messages, the AUX column is empty if the
fax was successful. The most common result codes listed
are for the END PLAY event.
01
02
03
04
05
06
07
08
09
Fax protocol error
Default error code
Modem training failure
Remote fax requested a feature not
supported by the Octel 200/300
Not used
Voice bus timeout
Fax protocol error
VCU software not ready
Bad-page-retransmit limit reached
0A
0B
0C
0D
0E
0F
Modem connection failure; no response
from on-board modem
Modem connection failure
Other side disconnected
Operator assistance not supported in fax
Fax system ID match
No fax or busy line
FAX_MSG END_PLAY
(continued)
10
11
12
13
14
15
16
17
18
19
Transmitter failed in HDLC test. Used in
fax loopback test. Hardware error 63 is
logged
Receiver failed in HDLC test. Used in fax
loopback test. Hardware error 63 logged
Both transmitter and receiver failed in
HDLC test. Used in fax loopback test.
Hardware error 63 logged
Timeout occurred in HDLC test. Used in
fax loopback test. Hardware error 63
logged
No identification frame record from
remote fax
Remote fax did not respond to command
Unable to configure remote fax
Remote fax did not confirm
Octel 200/300’s transmission fax
parameters
Hardware training failed. No carrier
No response from RX for multipage
signal