INSTALL 1-17
Octel 200/300 S.4.1PB60019−01
Port INFORMATION Table Indexes
The following indexes are applicable to port INFORMATION Tables. Refer to the Configuration
volume, Information Table chapter, for details about each index.
- Index 1. Each port/trunk INFORMATION Table must have an intercept position. The mailbox
must already exist in the USER Table.
1. INTERCEPT MAILBOX
(1−8 digits )
:
- Index 2. A company greeting mailbox can be configured. If a mailbox number is not entered,
the manufacturer’s recorded generic greeting is used.
2. COMPANY GREETING MAILBOX (1−8 digits, N = NONE, empty line = NONE )
:
- Index 3. The following index appears if the Incoming Call Restriction option is installed.
3. CALL BLOCKING NUMBER (0−255, 0 = NONE, empty line = NONE)
:
- Indexes 4 and 5. The following indexes appear if Single Digit Menus are used. Index 5 is not
listed if index 4 is NONE.
4. MAX DIGIT FOR MENU (0−8, 0 = NONE, empty line = NONE)
:
5. PREFIX DIGIT FOR MENU (1−7 DIGITS, N = NONE, empty line = NONE)
:XX
WARNING: The following MAILBOXES must exist in the USER TABLE or in a
COLOCATED cabinet:
- Indexes 6, 7, 9, 10, and 18. The following five indexes are listed.