Avaya Octel 200 Server User Manual


 
8-38 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
72 Protocol Revision
Level Error
Namesend activity Disable Namesend to the remote location. 1
DATA-1 = Digital Networking
DATA-2 = Local Protocol Revision Level
DATA-3 = Remote Protocol Revision Level
DATA-4 = Location number of Remote Location
73. Control Bus
Error – VCU
shared RAM I/O
Dependent on value in
DATA-2.
Replace VCU. If error repeats, contact your
technical support center.
3
DATA-1 = Task Number
DATA-2 = 01 VCU to CPU
02 CPU to VCU
74 Gateway Timeout
error
Message server timed
out waiting for the
gateway poll.
The OctelAccess server is not responding.
Check and bring up the OctelAccess server.
3
DATA-1 = OctelAccess ID (the ID configured at the OctelAccess server)
75 Names Directory
Export error
Message server
detected error when
updating Names
Directory export file
or during export file
transfer.
Contact your technical support center. 2
DATA-1 = ERROR CODE:
01 = NO DISK SPACE
02 = READ ONLY VOLUME
03 = ROOT DIRECTORY FULL
04 = NO SYSTEM DEVICE
05 = FILE CONTAINS BAD SECTORS
06 = NOT A FILE SYSTEM DRIVE
78. Network Message
Delivery Time
Out
Message server
determined that a
network message
failed to be sent after
the remote connection
was established
because the protocol
between the two
servers did not
complete correctly.
Monitor network queue. Delivery attempt
will retry; success is likely on the second or
subsequent attempt. Use @LOCNAM
command to identify the network location.
DATA-1=0
DATA-2= Network location
DATA-3= Message header number
1