Avaya Octel 200 Server User Manual


 
System Errors and Traffic Pegs 8-21
Octel 200/300 S.4.1PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
DATA-1
Bit 7: +5 volts clean out of range.
Bit 6: +5 volts VCC out of range.
Bit 5: Analog to Digital Converter error.
Bit 4: Interval timer error.
Bit 2: DRAM address or pattern error.
Bit 1: EPROM/Flash checksum error.
Bit 0: Fatal Processor error.
DATA-2
Bit 7: DMA page register error.
Bit 6: Unexpected interrupt error.
Bit 4: Temperature out of rage.
Bit 3: 12 volts out of range.
Bit 2: 5 volts clean out of range.
Bit 1: +12 volts motor supply out of range.
Bit 0: +12 volts clean out of range.
DATA-3
Bit 7: TDM crosspoint pattern or address error.
Bit 6: Modem loopback or download error.
Bit 5: UART channel 1 or 2 error.
Bit 4: Watchdog timer error.
Bit 3: Optional Control chip error.
Bit 2: Floppy disk controller error.
Bit 1: Real Time Clock error.
Bit 0: DMA register or transfer error.
DATA-4
Bit 7: Internal status register error
Bit 6: Ethernet Controller error.
Bit 5: Voice Bus Controller error.
Bit 4: SCSI Controller error.
Bit 3: TDM Codec loopback error.
Bit 2: Board Information Chip error.
Bit 0: Control Bus Controller / shared memory error.
36. System RAM
Error
Cache module found
an error with system
RAM, CPU and/or
VCU.
Call your technical support center for
remedy.
3
The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data
associated with the error.
DATA-1 = ERROR CODE:
01 = FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE