Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix D
E5jK Digital Controller Write Protocol
185
Switch to Level 1 (Sequence No. 075)
Switches the setting level to level 1 (setup mode, extended mode). This sequence can be executed for multiple
units.
Send Data Word Allocation (2nd Operand of PMCR)
(Undefined)
Unit No.
First word of
send data
Number of send data words+0
+1
+2
+3
+9
(Undefined)
Unit No.
Number of units
(Undefined)
Unit No.
~ ~
(max.)
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
Number of units + 2
+1 Number of units (4 digits BCD) 0001 to 0008
+2 to 9 Unit No. (2 digits BCD) 00 to 31
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Software Reset (Sequence No. 076)
Resets the operation of the E5jK (equivalent to turning on the power supply). This sequence can be executed for
multiple units.
Send Data Word Allocation (2nd Operand of PMCR)
(Undefined)
Unit No.
First word of
send data
Number of send data words+0
+1
+2
+3
+9
(Undefined)
Unit No.
Number of units
(Undefined)
Unit No.
~ ~
(max.)
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
Number of units + 2
+1 Number of units (4 digits BCD) 0001 to 0008
+2 to 9 Unit No. (2 digits BCD) 00 to 31
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note Communications with the E5jK are disabled for about five seconds after this sequence is executed.