Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix K3Z4L Laser Micrometer Protocol
318
Sequence
No.
Ladder interfaceFunctionCommunications sequence
name
Sequence
No.
Receive
word
allocation
Send word
allocation
FunctionCommunications sequence
name
418 All statistic memory clear
(3000-series)
Clears statistic processing memories of all
programs.
No No
419 Statistic memory clear
(3000-series)
Clears statistic processing memories of
program under display.
No No
420 Statistic result request
(3000-series)
Requests statistic processing result. No Yes
421 Memory switch set 1
(3000-series)
Sets memory switches. Yes No
422 Memory switch set 2
(3000-series)
Sets memory switches. Yes No
423 Simple AVG times set
(3000-series)
Taking the simple average as the averag-
ing method, sets the averaging times per
measurement interval 4.
Yes No
424 AVG move interval set
(3000-series)
Taking the average move as the averag-
ing method, sets the measurement inter-
val number.
Yes No
425 AVG move (H) times set
(3000-series)
Taking the average move and high-speed
data output as the averaging method, sets
the averaging times per measurement in-
terval 4.
Yes
No
426 AVG move (L) times set
(3000-series)
Taking the average move and low-speed
data output as the averaging method, sets
the averaging times per measurement in-
terval 4.
Yes No
427 Automatic detection set
(3000-series)
Sets work automatic detection function. Yes No
428 Automatic detection release
(3000-series)
Releases the settings of work automatic
detection function.
No No
429 Automatic detection list re-
quest (3000-series)
Requests the settings of work automatic
detection function.
No Yes
430 3Z4L initialize (3000-series) Clears the 3Z4L, sets the mm unit, sets
the memory unit, does not processes sta-
tistics, and clears all statistic memory.
Yes No
431 Measurement condition set
(4000-series)
Sets measurement conditions. Yes No
432 Measurement condition re-
lease (4000-series)
Releases measurement conditions that
have been set.
Yes No
433 Measurement condition list re-
quest (4000-series)
Requests the measurement conditions
that have been set and other settings.
No Yes
434 Single run measurement start
(4000-series)
When the sample measurement condition
is from 1 to 999, performs a single run
measurement and requests the measure-
ment results.
No Yes
435 Deflection measurement start
(4000-series)
Starts a deflection measurement. No No
436 Continuous measurement
start (scan) (4000-series)
Starts a continuous measurement. The
scan notification method is used for re-
ceive data.
No Yes
437 Continuous measurement
start (interrupt) (4000-series)
Starts a continuous measurement. The
interrupt notification method is used for
receive data.
No Yes
438 Measurement termination
(4000-series)
Terminates continuous measurement. No No
*1