Appendix K3Z4L Laser Micrometer Protocol
318
Sequence
No.
Ladder interfaceFunctionCommunications sequence
name
Sequence
No.
Receive
word
allocation
Send word
allocation
FunctionCommunications sequence
name
418 All statistic memory clear
(3000-series)
Clears statistic processing memories of all
programs.
No No
419 Statistic memory clear
(3000-series)
Clears statistic processing memories of
program under display.
No No
420 Statistic result request
(3000-series)
Requests statistic processing result. No Yes
421 Memory switch set 1
(3000-series)
Sets memory switches. Yes No
422 Memory switch set 2
(3000-series)
Sets memory switches. Yes No
423 Simple AVG times set
(3000-series)
Taking the simple average as the averag-
ing method, sets the averaging times per
measurement interval 4.
Yes No
424 AVG move interval set
(3000-series)
Taking the average move as the averag-
ing method, sets the measurement inter-
val number.
Yes No
425 AVG move (H) times set
(3000-series)
Taking the average move and high-speed
data output as the averaging method, sets
the averaging times per measurement in-
terval 4.
Yes
No
426 AVG move (L) times set
(3000-series)
Taking the average move and low-speed
data output as the averaging method, sets
the averaging times per measurement in-
terval 4.
Yes No
427 Automatic detection set
(3000-series)
Sets work automatic detection function. Yes No
428 Automatic detection release
(3000-series)
Releases the settings of work automatic
detection function.
No No
429 Automatic detection list re-
quest (3000-series)
Requests the settings of work automatic
detection function.
No Yes
430 3Z4L initialize (3000-series) Clears the 3Z4L, sets the mm unit, sets
the memory unit, does not processes sta-
tistics, and clears all statistic memory.
Yes No
431 Measurement condition set
(4000-series)
Sets measurement conditions. Yes No
432 Measurement condition re-
lease (4000-series)
Releases measurement conditions that
have been set.
Yes No
433 Measurement condition list re-
quest (4000-series)
Requests the measurement conditions
that have been set and other settings.
No Yes
434 Single run measurement start
(4000-series)
When the sample measurement condition
is from 1 to 999, performs a single run
measurement and requests the measure-
ment results.
No Yes
435 Deflection measurement start
(4000-series)
Starts a deflection measurement. No No
436 Continuous measurement
start (scan) (4000-series)
Starts a continuous measurement. The
scan notification method is used for re-
ceive data.
No Yes
437 Continuous measurement
start (interrupt) (4000-series)
Starts a continuous measurement. The
interrupt notification method is used for
receive data.
No Yes
438 Measurement termination
(4000-series)
Terminates continuous measurement. No No