Appendix I
K3Tj Intelligent Signal Processor Protocol
292
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0004 to 0098
+1 Number of units
(2 digits BCD)
01 to 32
+2 Bank No.
(2 digits BCD)
01 to 04
+3 to
+4
Set value
(5 digits BCD)
00000 to 99999
Negative sign: F (most significant digit)
Example 12345
+2
+3
2345
0001
Example –1234
+2
+3
1234
000F
D
D
D
+96 to
+97
Set value
(5 digits BCD)
Same as above
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Write Set Value H with Bank (Continuous Units)
(Sequence No. 309)
This sequence writes set value H of a bank not in use for continuous units. The word allocation is identical to that of
sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value L with Bank (Continuous Units)
(Sequence No. 310)
This sequence writes set value L of a bank not in use for continuous units. The word allocation is identical to that of
sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value LL with Bank (Continuous Units)
(Sequence No. 311)
This sequence writes set value LL of a bank not in use for continuous units. The word allocation is identical to that
of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O5 with Bank (Continuous Units)
(Sequence No. 312)
This sequence writes set value O5 of a bank not in use for continuous units. The word allocation is identical to that
of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O4 with Bank (Continuous Units)
(Sequence No. 313)
This sequence writes set value O4 of a bank not in use for continuous units. The word allocation is identical to that
of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O3 with Bank (Continuous Units)
(Sequence No. 314)
This sequence writes set value O3 of a bank not in use for continuous units. The word allocation is identical to that
of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).