Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix LVisual Inspection System Protocol
363
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002
+1 Scene No. (2 digits BCD) 00 to 15
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. If a scene No. is abnormal, CIO 28909 (if port A is used) or CIO 28913 (if port B is used) will turn ON.
2. Retry processing is not performed for this sequence.
3. Turn the Abort Bit ON and then OFF to end this sequence.
Inspection Execution and Character Inspection (F350)
(Sequence No. 473)
This sequence carries out one inspection and outputs the inspection results to a video monitor.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Character String Inspection and Character Inspection (F350)
(Sequence No. 474)
This sequence changes the inspection character string of a designated inspection area No. to a designated char-
acter string.
Send Data Word Allocation (2nd Operand of PMCR)
Designated character string
Designated character string
First word of send
data
Number of send data words+0
+1
+2
+3
(Undefined)
Number of designated character strings
Inspection area No.
~ ~
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0004 to 0015
+1 Number of designated character
strings (4 digits BCD)
0 to 24
+2 Inspection area No.
(2 digits BCD)
00 to 07
+3 to Number of designated character
strings (ASCII)
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Camera Change (Decrease by 1) (F200/300) (Sequence No. 480)
This sequence decreases the display camera No. by 1.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.