Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix LVisual Inspection System Protocol
365
Scene Switching (Arbitrary) (Sequence No. 492)
This sequence switches to a designated scene No.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
(Undefined)
Scene No.
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002
+1 Scene No. (2 digits BCD) 00 to 15
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Measurement, Inspection Termination (Sequence No. 493)
This sequence terminates the measurement and returns to the home menu.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
General-purpose Command (Send) (Sequence No. 494)
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is auto-
matically attached to the send data.
Send Data Word Allocation (2nd Operand of PMCR)
Command length
Command
First word of
send data
Number of send data words+0
+1
+2
(Undefined)
~ ~
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
003 to 0129
+1 Command length (4 digits BCD) 0001 to 0253
+2 to Command (ASCII) Specify ASCII data.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. The processing depends on the command.
2. For a command with a response, use sequence #495.
General-purpose Command (Send/Receive) (Sequence No. 495)
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is auto-
matically attached to the send data.
Send Data Word Allocation (2nd Operand of PMCR)
Command length
Command
First word of
send data
Number of send data words+0
+1
+2
(Undefined)
~ ~